Type |
swiss air PAPR system, battery powered |
Protection Levels |
NIOSH PAPR-100N |
Flow Rates |
level 1: min. 120 l/min
level 2: min. 130 l/min
level 3: min. 140 l/min
All levels with automatic air flow control (levels are set directly on the fan and can be continuously adjusted via the control panel at the front). |
Material |
PA66 GF30 |
Fan |
High-quality ball beared motor |
Fuse |
Electronic |
Noise |
max. 60db (A) |
Alarm |
optical (with swiss air Control Panel) and audible alarm for low / very low battery, clogged filter, no filter, and low flow
Low battery: alarm period: 3.0s (1.5s on, 1.5s off)
Filter: alarm period 0.5s (0.25s on, 0.25s off) |
Dimensions (L x W x H) |
250 x 170 x 50 mm |
Weight |
1200 g / 42,15 oz (incl. filter, belt and battery)
550 g / 19,400 oz (excl. harness and battery) |
Color |
Black |
Material |
Silicon, POM (exhalation valves & connectors) |
Valves |
2 exhalation valves with silicone membrane |
Color |
transparent-white |
Material |
Neoprene / elastic |
Color |
Black |
Type |
NIOSH PAPR-100N with pre-filter |
Hose |
POM and silicone |
Length |
180 mm (elastic, up to 355 mm excl. Y-hose) |
Internal diameter |
21 mm |
Color |
Black |
Type |
Li-Ione, rechargeable, 3,6 V / 6,5 Ah / 23.4Wh |
Operating time |
level 1: 10h
level 2: 8h
level 3: 6h
(with new filter at room temperature) |
Type |
Li-Ione, rechargeable, 3,6 V / 6,5 Ah / 23.4Wh |
Charging time |
appr. 6h |
Sleep mode |
after 3 hours, activation by pressing once button |
Standards |
NIOSH-PAPR100-N |
Notified body |
NIOSH Approval TC-21C-1363 |
Scope of Delivery |
Blower unit with hose, PAPR-100N filter, spark protector, battery, harness, control panel, charger, carrying backpack, user instructions (mask sold separately) |
Warranty |
2 years from date of sales for manufacturing and material defects, 6 months for battery |
Note |
The optrel swiss air respiratory system may NOT be used in environments where there is an immediate danger to health or life (IDLH), in atmospheres containing less than 17% oxygen or where the concentration of toxins is so high that a protection class in excess of a fit factor higher than 500 is required. It is NOT evaluated as an ignition source in flammable or explosive atmospheres. |